Regulation & Policy

SP 188 Exemption Lets 416 kWh of Batteries Sail Undeclared in One Box

Package-level relief under SP 188 leaves no cap on total battery energy per container. A fix via IMDG cycle 44-28 only bites in 2030, so CINS urges a 20 kg per CTU benchmark now.

Op-Ed: Rising Demand for Batteries Exposes Gaps in Shipping Regulations - The Maritime Executive
Exhibit · Op-Ed: Rising Demand for Batteries Exposes Gaps in Shipping Regulations - The Maritime Executive — Pexels / pixabay

Adjustments

  1. Some 4,200 laptops at 99 Wh each can ship in one 40ft box undeclared under SP 188 — about 416 kWh of stored energy.
  2. McKinsey projects a 6.8 TWh global battery market by 2035, over 85 percent Li-ion driven.
  3. Any SP 188 reform enters force via IMDG cycle 44-28 on January 1, 2030, leaving a multi-year gap.
  4. CINS recommends capping SP 188 relief at 20 kg gross battery mass per CTU.
  5. SSE 12 has finalized draft SOLAS amendments on thermal imagers and water mist lances for containerships.

A single 40-foot container can legally carry around 4,200 laptops — roughly 416 kWh of stored lithium-ion energy — with no dangerous goods declaration and no placard, because every 99 Wh battery qualifies for relief under Special Provision 188 of the IMDG Code. That arithmetic, laid out by UK P&I Regional Loss Prevention Director Akshat Arora, frames what the industry now treats as a live regulatory gap.

The exposure is growing fast. McKinsey & Co. projects a global battery market of 4.2 TWh in 2030 and 6.8 TWh by 2035, with more than 85 percent of that demand driven by Li-ion batteries. For carriers, insurers and logistics partners, the trend sharpens the question of how these cargoes are stowed, segregated and monitored.

Why is thermal runaway so hard to manage?

Li-ion batteries present two distinct problems. The first is the speed and severity of a fire once one starts. The second is that SP 188 lets large quantities of smaller cells move through the transport chain undeclared.

A cell that is damaged, defective, overcharged or heated can enter thermal runaway — a self-accelerating reaction in which rising temperature drives further chemical decomposition and more heat. In a densely packed container, one failure can cascade cell to cell.

Some cargo fires give warning through smoke or a slow temperature rise. Thermal runaway can develop quickly and stay undetected early. The fire is also self-sustaining: knocking down visible flames doesn't stop the reaction inside the battery, and re-ignition remains a risk. Effective cooling, mainly through water where it can be applied, is critical to limiting propagation.

What is the regulatory gap?

SP 188 offers conditional relief for cells up to 20 Wh and batteries up to 100 Wh, provided testing, packaging, marking and short-circuit protection criteria are met. The difficulty is that these safeguards apply only at cell, battery and package level.

A joint submission to the IMO's Sub-Committee on Carriage of Cargoes and Containers (CCC 12), backed by several flag states, industry organizations and P&I clubs, put it plainly: "Whilst SP 188 contains package-level limits and safeguards, there is currently no equivalent limit on the total quantity of batteries that may be loaded within a single freight container."

The Cargo Incident Notification System (CINS) reached the same conclusion in a recent recommendation paper, stating that SP 188 no longer fully meets the safety and traceability needs of current maritime and port operations.

The problem is wider than containerships. On vehicle carriers and Ro-Ros, Arora writes, the concern is not that electric vehicles catch fire more often than combustion cars, but that thermal runaway, re-ignition and toxic gases make incidents harder to manage — particularly with secondhand EVs of unclear battery condition. Batteries hidden in scrap metal and e-waste cargoes on bulk carriers can be damaged during handling or compaction, creating severe firefighting challenges around cargo volume, access and stability.

What is being done?

The IMO's Sub-Committee on Ship Systems and Equipment (SSE 12) has finalized draft SOLAS amendments on portable infrared thermal imagers and water mist lances for containerships. Equipment alone isn't enough, Arora argues: if the crew doesn't know a container holds Li-ion batteries, or in what quantity, emergency response decisions get much harder.

The joint submission to CCC 12 proposes a cargo transport unit (CTU) level threshold, based on gross mass or watt-hours, above which dangerous goods documentation and potentially placarding would apply. Any change, though, comes through IMDG amendment cycle 44-28, mandatory from January 1, 2030 — leaving more than three years with the gap open.

The shore side is equally thin. A recent white paper by UK P&I, TT Club and Brookes Bell, Warehouse Storage of Lithium-ion Batteries, found no mandatory global standards for battery storage. Processes rely on voluntary guidance, with liability set through non-standardized contracts.

What should shippers and carriers do now?

CINS recommends capping SP 188 relief at a 20 kg gross battery-mass threshold per CTU, with mandatory declarations even below that level. It's an industry benchmark, not a Code requirement, but it gives operators a working line until regulation catches up.

Arora's mitigation list for the interim:

  • Declare Li-ion battery presence and quantity at booking even where SP 188 doesn't require it
  • Keep UN 38.3 test summaries available on request
  • Handle damaged or defective batteries under SP 376, and disposal or recycling shipments under SP 377 — neither as ordinary SP 188 cargo
  • Treat cumulative battery content per container as a risk factor in its own right
  • Flag battery containers on the load list so stowage planning reflects the hazard
  • Apply know-your-shipper checks to vague or unusual cargo descriptions, plus random tailgate inspections and thermal imaging before loading
  • Quarantine damaged or suspect units, monitor temperatures and define firefighting protocols

Through the Safetytech Accelerator's Cargo Fire & Loss Innovation Initiative (CFLII), UK P&I and TT Club are working with shipping lines and technical experts to evaluate earlier detection — multi-sensor systems, infrared monitoring and fiber-optic heat detection.

The core message: SP 188-exempt cargo is not low-risk cargo, whether it sits in a warehouse, a terminal stack or a ship's hold. Accurate information at every stage supports effective response, root-cause analysis and recovery, and prevention beats the cure.

via Google News: Container Shipping (Source)

Share this article:

More from Sophie Lindqvist

Sophie Lindqvist

Show full bio

Market editor covering technology and product news in commercial shipping for industry professionals at Vessels.

199 articles

Linked entries

  1. Korean LNG insulation duopoly eyes US export project windfall
  2. Battery swapping undercuts market-priced HVO by 22% in 110-metre model
  3. EU's 350,000-unit cap on Chinese hybrids threatens FVL volumes
  4. ZPMC lands first electric reach stackers in Europe at Gdynia
  5. GTT to design NO96 Super+ tanks for five MISC LNG carriers

▲ Previous article